ChromoTek iST TurboGFP-Trap Kit for AP-MS sample preparation of TurboGFP-fusion proteins

Kit for IP/ Co-IP of TurboGFP-tagged proteins & sample preparation for mass spectrometry (MS)

Specificity

TurboGFP, CopGFP, maxGFP

Applications

IP, MS

Conjugate

Agarose

Type

Nanobody

Cat No : tbtak-iST

Synonyms

TurboGFP-Trap, TurboGFP, CopGFP, maxGFP,maxFP-Green, green fluorescent protein CopGFP, TurboGFP tag



Product Information

Kit for IP/ Co-IP of TurboGFP-tagged proteins & sample preparation for mass spectrometry (MS)

DescriptionThe iST TurboGFP-Trap Kit enables researchers to process TurboGFP-fusion proteins and their interacting partners for Mass Spectrometry analysis by including the ChromoTek TurboGFP-Trap for immunoprecipitation/Co-IP of TurboGFP-fusion proteins and the PreOmics iST buffers and cartridges required for bottom-up proteomic sample preparation. This robust method yields purified peptides while dramatically reducing contamination and sample loss. Each kit accommodates up to eight samples and includes pull-down reagent for controls:

• Reliable dentification of TurboGFP-fusion proteins & interacting partners by MS

• Identification of even low abundant/ low expressed TurboGFP-fusion proteins

• Superior processing of IP samples into clean peptide mixtures

• Intuitive protocol and reproducible results

ApplicationsIP, MS
Specificity/TargetTurboGFP, CopGFP, maxGFP, maxFP-Green
For the complete list, please click here: Fluorescent protein specificity table
Binding capacity7.5-10 μg of recombinant TurboGFP per 25 μL bead slurry
ConjugateAgarose beads; bead size: ~ 90 µm (cross-linked 4 % agarose beads)
Type Nanobody
ClassRecombinant
HostAlpaca
Affinity (KD) Dissociation constant KD of 0.5 nM
Compatibility with mass spectrometryThe TurboGFP-Trap is optimized for on-bead digestion.
Storage Buffer20% ethanol
Storage ConditionKit is shipped at ambient temperature. Upon receipt store TurboGFP-Trap at 4°C and Digest at -20°C

Kit components

ComponentDescription
TurboGFP-Trap Agarose8 reactions plus 2 controls
DigestEnzyme Trypsin-mix to digest proteins.
Resuspend bufferProtease reconstitution buffer for enzymes.
Lyse bufferDenature, reduce and alkylate proteins.
Stop solutionStop the enzymatic activity.
Wash 1 bufferClean up peptides from hydrophobic contaminants.
Wash 2 bufferClean up peptides from hydrophilic contaminants.
Elution bufferElute the peptides from the cartridge.
LC-Load loadLoad peptides on reversed-phase LC-MS column.
CartridgesCartridge for 1 to 100 µg protein starting material.
Waste tubesTube for collecting waste after washing steps.
Collection tubesTube for collecting peptides after elution.
AdaptersEnables placing a cartridge into a tube.
CapsCap to optionally close the cartridge’s bottom.